• Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
  • Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
  • Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
  • Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
  • Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
  • Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water

Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water

Certification: CE
Salt Rejection Rate: 99.5%
Application: Industry
Capacity: 1000lph
Applicable Industries: Hotels, Machinery Repair Shops, Home Use
Core Components: Pump, RO Membrane
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Jiangsu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 9 foreign trading staff(s) and 6 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Overview
  • Related Products
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Project Case
  • Company Profile
Overview

Basic Info.

Model NO.
1000LPH
OEM
Support
Power
110V/220V/380V/430V
Desalination Rate
99%
Transport Package
Wooden Case
Specification
250LPH, 500LPH, 1000LPH ect
Trademark
Customizable
Origin
China

Product Description

Related Products
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water

                   FRP Tank                                                  PP Filter Housing                                          Industrial RO Membrane
Product Description

1000LPH 6000GPD RO System 

RO Plant working cycle:
Step 1: Water is fed to the raw water pump into the sand filter, which removes suspended solids from water.
Step 2: The water then flows to the activated carbon filter for dichlorination.
Step 3: The water then flows to the resin softener filter for softening.

Step 4:  Water is further passed to a micron cartridge filter for fine filtration.
Step 5: Water is then pumped by a high-pressure pump into the RO membranes.
Step 6: Pure water passes through the membranes, while most dissolved solids do not pass through the membrane.
Step 7: The pure water then passes through the RO product line, and the contaminated water passes through the reject line or recycle line. 
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
What does a reverse osmosis system remove?
A reverse osmosis system removes dissolved solids like arsenic and fluoride through the RO membrane. An RO system also includes sediment and carbon filtration for a broad spectrum of reduction. The carbon filters in an RO system remove chlorine, bad taste, and foul odors, and the sediment filter removes dirt and debris.
Does a reverse osmosis system remove…
Fluoride?------Yes.
Salt?------ Yes.
Sediment?------ Yes.
Chlorine?------ Yes.
Arsenic? ------Yes.
VOCs? ------Yes.
Herbicides and pesticides?------ Yes.
Many other contaminants? ------Yes. The contaminants listed are some of the most popular ones treated with an RO system, but the system also removes a slew of other contaminants.
Bacteria and Viruses?------ No. If your water comes from a city treatment plant, then it should already be microbiologically safe. Reverse osmosis may remove some bacteria, but bacteria could grow on the membrane and potentially enter your water supply. To remove living organisms and viruses, we recommend UV disinfection.Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
 
Product Parameters

 Reverse Osmosis System is built of five basic parts:

 

1) Pressure RO Vessel & Membrane
Obviously, a reverse osmosis system wouldn't get very far without membrane elements. The proteins that make up membrane elements vary depending on the kind of intake water and ending clarity. There are membrane elements for brackish water, seawater, hospital-grade disinfection, and membranes designed to remove specific contaminants to name a few. If there is a water treatment need, you can be sure there is certainly a membrane element for the job. The size of the task (municipal, commercial, or industrial) will determine the size and number of reverse osmosis membranes in a system. There can be anywhere from a single two and a half inch membrane (like in an under-sink reverse osmosis water system) to hundreds of eight inch membranes all working together (a typical reverse osmosis plant).
2) SS Frame
The best way to make your reverse osmosis system as durable as possible is with a powder coated, carbon steel frame to mount all of your components on. It's resistant to the elements, designed for the heavy vibration of high-pressure pumps, and  mounts to the ground to ensure that it will last a lifetime.
3) Cartridge Filter
Most reverse osmosis water systems come with a cartridge filter to ensure that no particles large enough to damage the membranes come anywhere near them. This cartridge is usually a five micron spun polypropylene filter, but can vary upon request. The cartridge comes in a durable casing that can handle the pressure from the main feed or booster pumps.
4) Reverse Osmosis High Pressure Pump
Without a high-grade pump, the rejection rate for a reverse osmosis system isn't viable in most commercial or industrial settings. It is vital to the system to ensure that the pump is matched to the membrane quantity and size appropriately. Usually, the higher the horsepower on the intake pump, the better the rejection and recovery rates of permeate.
5) Control Panel
Lastly, the reverse osmosis system has to be controlled by a human operator. At Pure Aqua, we use advanced PLCs or a solid-state microprocessor depending on how advanced the controls need to be. The controls can also be used to manage multiple systems simultaneously, effectively making a one-man water production plant.

A reverse osmosis system can have a number of other components built onto or into it as extra components as well. The entire skid can be built into a containerized system, for example, so your Desalination by RO System is always on the go. There are a number of supplemental skids that can be attached to an RO System as well, for tasks like membrane cleaning, pretreatment, chemical dosing, and a number of other jobs as necessary.
 

Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Packaging & Shipping
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water
Project Case

Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water

Company Profile

Industrial 6000gpd 1000lph Reverse Osmosis RO Water Purifier Filter System Plant for Drinking Water

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now